Warning: Attempt to read property "ID" on null in /home/oursymp/public_html/wp-content/plugins/subscribe-to-comments/subscribe-to-comments.php on line 212
Warning: Cannot modify header information - headers already sent by (output started at /home/oursymp/public_html/wp-content/plugins/subscribe-to-comments/subscribe-to-comments.php:212) in /home/oursymp/public_html/wp-content/plugins/modern-events-calendar-lite/app/libraries/main.php on line 3447
Warning: Cannot modify header information - headers already sent by (output started at /home/oursymp/public_html/wp-content/plugins/subscribe-to-comments/subscribe-to-comments.php:212) in /home/oursymp/public_html/wp-content/plugins/modern-events-calendar-lite/app/libraries/main.php on line 3448
BEGIN:VCALENDAR
VERSION:2.0
METHOD:PUBLISH
CALSCALE:GREGORIAN
PRODID:-//WordPress - MECv6.5.5//EN
X-ORIGINAL-URL:https://oursymposium.sites.unlv.edu/
X-WR-CALNAME:Office of Undergraduate Research (OUR) Fall 2021 Virtual Undergraduate Research Symposium
X-WR-CALDESC:
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-PUBLISHED-TTL:PT1H
X-MS-OLK-FORCEINSPECTOROPEN:TRUE
BEGIN:VEVENT
CLASS:PUBLIC
DTSTART;TZID=UTC:20211115T000000
DTEND;TZID=UTC:20211120T000000
DTSTAMP:20211028T000000
UID:MEC-c61f571dbd2fb949d3fe5ae1608dd48b@oursymposium.sites.unlv.edu
CREATED:20211028
LAST-MODIFIED:20211110
PRIORITY:5
TRANSP:OPAQUE
SUMMARY:HNSE-O1-3. Hydrogels LCST
DESCRIPTION:Genaro Marcial Lorza1\nSantiago Ricoy1\nFaculty Mentor: Jeremy Cho, Ph.D.1\n1Howard R. Hughes College of Engineering, Department of Mechanical Engineering\nABSTRACT\nHydrogels are three-dimensional polymer lattices that are absorbent and can uptake or retain a large amount of water for their size. Some hydrogels spontaneously de-swell above a specific temperature. Observation of this type of behavior has been limited to one type of hydrogel: poly(N-isopropyl acrylamide) – PNIPAM (pronounced “ny-pam”). If PNIPAM is below the lower critical solution temperature (LCST), the hydrogels are more hydrophilic (i.e. they absorb more water), in contrast, if the temperature is higher than LCST, then the gels become less hydrophilic, the hydrogels hold less water, thus, water content will be released. We designed a water bath system device using a stainless steel container and a floating glass container. The hydrogel is submerged in the small glass container. The outer container is filled with water that is connected to a magnetic drive pump that circulates water effectively as it is being heated with two 60 Watts cartridge heaters. A plexiglass lid was added to the outer container to maintain constant heating temperatures. As we increased the temperature of the water to 35°C the hydrogel sample began to deform and expand abnormally. We expected the hydrogel to contract but were unable to see this effectively since it was submerged in water. We conclude that in order to see more swelling behaviors and biodegradability LCST could be introduced to PAAm hydrogels by incorporating a controlled fraction of PNIPAM into the polymer lattice varying increments in the temperature range of 20°C and 30°C instead of 35°C.\n
URL:https://oursymposium.sites.unlv.edu/program/hydrogels-lcst/
ORGANIZER;CN=The Office of Undergraduate Research:MAILTO:our@unlv.edu
CATEGORIES:Health & Natural Sciences & Engineering
END:VEVENT
END:VCALENDAR